Wind on monoslope roofs with a slope between 3 and 30 degrees for C&C
Figure 4.1.7.6.-G (NBC2020)
v1.0.0
File:
Project:
Designer:
Date:

Climatic Data

Location
Province:
Reference Velocity Pressure
q:

Factors

Importance factor
Category:
Limit state:
Exposure Factor
Terrain:
Height, h:
m (Reference height in meters above grade)
Topographic Factor
Ct:
Internal pressure
Category, Cpi:
Midheight of dominant opening (for Cei)
Midheight, hi:
m (leave empty if no dominant opening.)

Building

Roof pitch:
/12
Tributary Area, A:
m2
End-zone width, z
(If H or the least horizontal dimension are left blank, z will not be calculated.)
Building Height, H:
m (Height of building at eave)
Least horizontal dim:
m
Region
Region 'c'
Region 'r'
Region 's'
wind mono slope 10 - 30

Factors

User input values:
q: 1kPa
Importance Factor, ULS: Iw = 1.0
Ce = (h/10)0.2 (but not less than 0.9) = 0.9
Roof slope: 26.57 degrees

External Wind Pressure

Using figure for monoslope roofs with slopes between 10 and 30 degrees.
Zone CpCg pe (kPa)
c'--5.47-4.92
r--2.5-2.25
s--3-2.7
c+0.80.72
r+0.80.72
s+0.80.72

Internal Wind Pressure

Cgi = 2
Cpi = -0.45 to 0.3
Reference height (max H/2 or 6m)= 6 m
Cei = (hi/10)0.2 (but not less than 0.9) = 0.9

pi = Iw*q*Ce*Ct*Cgi*Cpi
pi = -0.81kPa to 0.54kPa

Combined Wind Pressure

Zone Cpi=-0.45
p (kPa)
Cpi=0.3
p (kPa)
c'--4.11-5.46
c+0.181.53
r--1.44-2.79
r+0.181.53
s--1.89-3.24
s+0.181.53

End Zone Width

The end-zone width is the lesser of:
• 10% of the least horizontal dimension = 0.1m
• 40% of the height of the building (H) = 0.4m
but not less than:
• 4% of the least horizontal dimension = 0.04m
• 1m
z = 1m